The Work
Real jobs, real results. Navien installs, slab repairs, water heaters, re-pipes — from the Inland Empire and beyond.
Open wall cavity in a bathroom remodel with a shower valve body, PEX supply lines, and a waterproofed shower pan visible during rough-in. Newly tiled shower enclosure with rough-in valve stub-outs and dual recessed niches installed in a bathroom remodel. Navien tankless water heater installed on garage wall with copper supply lines and PVC condensate drain. Navien tankless water heater installed open-faced on interior wall with PVC vent, PEX lines, and yellow gas flex visible. Navien condensing tankless water heater with visible corrosion and rust at the heat exchanger casing seam during a leak diagnosis. Close-up of a heavily corroded and mineral-encrusted water heater burner assembly with visible igniter wiring during diagnosis. Speakman combination emergency eyewash and drench shower station installed on a concrete block wall in an industrial facility. Black commercial floor-mount toilet with flush valve being serviced in a dark-tiled restroom, with Milwaukee drill and tool case on the floor. Corroded toilet flange exposed on a bathroom floor with tile removed, showing rust damage and failed wax ring seal. Navien tankless water heater installed in a closet with copper pipe connections, isolation valves, and stainless flex lines. Navien tankless water heater installed in an exterior alcove with copper and flexible gas lines connected below. Navien tankless water heater installed in an exterior recessed alcove with copper supply lines and condensate drain. Close-up of a Navien condensing heat exchanger on a tankless water heater with visible corrosion damage and wiring connections during diagnosis or repair. Tankless water heater installation in an exterior utility alcove of a residential stucco home, with copper supply lines and a ladder staged at the access panel. Navien tankless water heater installed in a utility alcove with copper supply lines and flexible gas and water connections below. Six Navien tankless water heaters with open front panels displayed on stands in a training room classroom setting. Three Navien tankless water heaters installed side by side in a utility room with PVC flue venting and yellow gas flex lines. Navien tankless water heater installed on a garage wall with copper supply lines, gas flex connector, and PVC vent piping overhead. New ABS drain and vent rough-in installed through floor framing during ground-up construction. New exterior wall framing with rough-in plumbing — black ABS drain lines and white PEX supply stubs installed through floor joists at a residential addition or bathroom build. ABS drain pipe being set and foam-sealed into a subfloor rough-in opening during a bathroom drain installation. New construction framing interior showing floor joists, metal stud walls, and rough-in plumbing conduit staged for installation. Black ABS drain pipes run through LVL floor joists during new construction framing in an open residential structure. Exterior backyard with exposed wood framing and floor joists laid over bare soil, showing subfloor structure during construction or deck rebuild. Newly installed walk-in shower with brushed nickel rain head, wall-mounted controls, marble-style porcelain surround, and penny tile floor inside a bathroom. Noritz tankless water heater installed in a garage alongside a whole-house water softener, sediment filter, and copper supply lines. Commercial restroom stall with a floor-mount toilet, flushometer valve, grab bars, and wet/stained concrete floor indicating an active leak or overflow. Commercial restroom stall with a floor-mounted toilet, flush valve, and water-damaged flooring around the fixture base. Commercial bathroom undergoing drain line replacement with slab cut open, exposing ABS drain stubs and supply lines through a wall access panel. Bathroom remodel in progress with large-format tile shower surround being installed, toilet in place, ceiling open. Exterior hose bib with brass ball valve and backflow preventer mounted on white pipe against stucco wall above a garden bed. ProFlo pressure gauge attached to an exterior hose bib on a stucco wall during water pressure diagnostic testing. ProFlo pressure gauge attached to an exterior hose bib on a white PVC supply line during water pressure testing. New alcove bathtub set in place during bathroom remodel, with rough framing exposed and black matte shower valve rough-in visible on tiled wall. New alcove bathtub set in place during bathroom remodel with surrounding tile and drywall partially removed. New PEX supply lines and shut-off valves roughed into an open wall cavity during a bathroom remodel. New shower valve and supply lines roughed in through open wall framing with pink insulation in a bathroom remodel. PVC drain pipe routed along interior wall near a commercial roll-up door, with HVAC equipment and ladder visible overhead. Navien tankless water heater installed on interior wall with copper supply lines, gas flex connector, and PVC flue venting through ceiling in a utility room. Navien tankless water heater installed on interior wall with gas flex line, water connections, recirculation pump, and ceiling exhaust vent. Technician holds a heavily corroded galvanized steel pipe section removed from a crawl space during drain or water line repair. Black ABS or cast iron drain pipe running through a crawlspace or attic framing with severe active corrosion/rust bleed at a threaded coupling joint, staining the wood joist below, indicating a long-term slow leak at that fitting. Heavily corroded cast iron drain pipe with active rust and moisture damage found in a crawl space during leak detection. Red-painted steel or cast iron pipe with a 90-degree elbow fitting, showing heavy scale buildup, surface corrosion at the threaded joint, and mineral deposits consistent with an aging hot water or steam heating supply line in a basement or mechanical space. ABS drain pipe with a wye fitting being installed or repaired in an exterior excavated trench connecting to an existing clay or cast iron sewer line. Technician stands beside a deep exterior excavation pit in a lawn, with a rotary hammer and shovel visible, accessing an underground line. Milwaukee drain snake fed into bathroom sink drain during clog clearing, with rubber gloves and rags on vanity countertop. Exterior irrigation system with multiple zone valves, a controller box, and copper supply line mounted at a home's siding. Technician holds a removed brass and aluminum valve cartridge with O-rings outdoors. Tiled shower wall cut open to access a corroded brass valve body with supply stub-outs during a repair. Active leak with water bubbling at a corroded threaded union fitting on an exterior black iron pipe at the house foundation. Exterior hose bib with galvanized pipe stub-up and shutoff valve mounted at a stucco wall near a concrete slab. Freestanding utility sink with black faucet being installed in a garage, with drill, fittings, and supply lines on the floor nearby. Black utility sink with faucet being installed in a laundry or utility room, with Milwaukee drills and fittings staged on the floor nearby. Bradford White electric water heater installed inside a wood cabinet enclosure with copper supply connections and earthquake straps. Tank water heater inside a wood-cabinet utility closet with an aluminum ladder and moving blankets staged for replacement work. New brass ball valve installed on a copper supply line at an exterior brick wall irrigation or hose bib connection. Newly installed brass pressure regulator on a copper main line at an exterior brick wall with a ground-level shutoff valve. Heavily corroded threaded steel fitting with hex nut transitioning to a braided stainless flexible supply line, showing significant surface rust and galvanic corrosion at the connection interface, removed from service. Bathroom rough-in with exposed 2x4 framing showing a PVC vertical drain stack, PEX supply lines with a shower valve rough-in valve body, and a slab floor stub-out for a toilet flange install. Exterior yard box or meter enclosure behind a galvanized chain-link fence, with a brass ball valve assembly visible in the background and black-and-white banded flex conduit or corrugated pipe risers in the foreground, likely a backflow preventer or irrigation shutoff installation at grade level. Exterior foundation wall showing a galvanized riser transitioning to copper with brass ball valves and a hose bib above grade, tying into a PVC stub-out at the base near a wet, excavated trench — galvanic corrosion risk at every dissimilar-metal union, with signs of active or recent ground saturation. Chrome single-handle lavatory faucet with vessel-style undermount vitreous china sink on marble vanity top, chrome pop-up drain assembly, flow appears unobstructed with no visible scale, corrosion, or aerator restriction. Chrome widespread lavatory faucet with square lever handles on a white undermount vitreous china sink set in marble countertop, running water, no visible corrosion or mineral scale on the spout or handles. Two chrome angle stop shut-off valves with braided stainless supply lines stubbing out of a textured drywall finish, showing minor water staining and efflorescence at the lower escutcheon, consistent with a bathroom sink or laundry rough-in. Dual-tank water softener with stainless brine/resin tanks plumbed in copper at the point of entry in a residential garage, with a blue whole-house sediment pre-filter canister and bypass valve assembly mounted to the wall. Dual-tank water softener system with a whole-house sediment pre-filter canister plumbed in copper at the main service entry in a garage, bypass valves installed, no visible corrosion or scale on exposed fittings. Exterior freeze-proof yard hydrant on galvanized riser with a SharkBite PEX push-fit elbow feeding a heavily corroded and rust-stained backflow preventer, mounted at grade against a brick wall with significant oxidation and mineral scaling throughout. Copper supply line stubbed through drywall with a brass ball valve and compression/push-fit fittings on both ends, foam-insulated flex connector on the outlet side, pipe clamp at the wall penetration, no visible corrosion. Two copper supply lines with 90-degree stub-outs are roughed in through an OSB-backed wall cavity, likely a shower or tub valve rough-in, with drywall opened for access and no visible corrosion or scale. ProFlo brass hose-thread pressure gauge screwed onto an exterior hose bib with a blue quarter-turn ball valve, reading approximately 75 psi static supply pressure against a stucco exterior wall. ProFlo brass hose-bib pressure gauge threaded onto an exterior hose bibb against a stucco wall, reading approximately 100 psi static supply pressure, with light surface oxidation on the brass fitting. Commercial stainless hand sink with deck-mount two-handle faucet and black ABS P-trap rough-in during an active interior remodel, drain not yet connected to floor, construction debris visible throughout. Commercial three-compartment stainless steel sink with wall-mounted pre-rinse spray assembly, chrome supply lines, black ABS drain plumbing below, and an inline water filter on the left wall, in a finished commercial kitchen utility room. Wall opened in a finished bathroom corner revealing ABS or black PVC drain line running along the base of the wall with a 90-degree sweep fitting, alongside exposed fiberglass batt insulation, foil vapor barrier, and what appears to be white PVC supply lines with push-fit fittings visible in the upper wall cavity — indicative of a leak investigation or drain reroute. Interior wall opened at baseboard level exposing black ABS or cast iron drain pipe with a banded coupling, visible PVC fittings in the cavity background, batt insulation, foil vapor barrier, and wood framing consistent with a leak investigation or drain re-route in a finished bathroom or hallway. Tankless gas water heater mounted in a recessed drywall alcove with copper water supply lines, yellow CSST flexible gas connector, white PVC combustion air/exhaust venting overhead, and galvanized steel drain piping at the base. Copper hard-pipe rough-in at slab level serving Atlas Copco commercial air compressors, with press-fit fittings being installed using a Milwaukee press tool; no visible corrosion or scale on new material. Outdoor shower rough-in on a stucco-finished masonry wall with matte black trim-kit valve and fixed showerhead, supply lines concealed in wall, no visible corrosion, adjacent bamboo privacy screen, appears to be a completed exterior installation. Outdoor commercial mechanical yard with stainless or galvanized steel pipe runs overhead on structural steel unistrut framing, flanking large black industrial tanks or chillers, with a tradesman on a ladder mid-installation on a concrete pad. Residential drywall ceiling cut open for leak investigation above a kitchen/living area, with framing and subfloor visible in the access hole, indicating active water intrusion from above requiring trace and repair of supply or drain line running through the floor/ceiling assembly. Two ceiling drywall access panels cut open above a kitchen sink area, exposing framing and likely overhead supply or drain lines, consistent with leak investigation or re-pipe access in a single-story residential kitchen. Kitchen cabinet base opened post-water-loss event showing an under-sink whole-house or point-of-use filtration canister with supply lines, flooring removed to concrete slab, and multiple air movers deployed for structural drying. Active water damage mitigation in a residential entryway with flooring removed down to concrete slab, commercial dehumidifiers and air movers deployed, indicating a significant supply or drain line failure beneath the finish floor. Water damage remediation in progress on a concrete slab subfloor with flooring removed, showing multiple axial air movers and a commercial dehumidifier deployed to dry out a residential living space after a water intrusion event. Drywall cut open at ceiling level in what appears to be a garage or utility area, exposing a black ABS drain pipe, copper or galvanized supply lines, and blue PEX stubs running through stud bays, with visible moisture staining on the framing suggesting prior leak damage. Exterior slab excavation showing a copper stub-out with foam pipe insulation rising from grade alongside an existing hose bib fed by galvanized supply line showing surface corrosion at the fitting connections. Single-handle pressure-balancing shower valve trim (likely Moen or Delta) set in ceramic tile surround, chrome escutcheon showing hard water mineral scale buildup, grout lines moderately stained indicating age, no visible supply or drain work. Laundry room wall opened up for water damage remediation, exposing copper supply lines and what appears to be blue PEX in the cavity, with wet/saturated insulation, mold-blackened framing, and a wet-vac hose staged for extraction. Failed copper sweat joint on an exterior or exposed masonry-adjacent line showing active pinhole seepage, heavy verdigris (green oxidation) buildup, and a blown solder bead — classic flux-acid corrosion or improper heat during original solder, needs cut-out and re-sweat or replacement coupling. Rheem Performance gas water heater installed in a utility closet on a raised concrete pad, with copper supply connections at the top, yellow CSST flexible gas line at the base, and corrugated stainless flex connectors on the inlet/outlet. Two matte black in-wall valve trim kits — left appears to be a pressure-balance shower valve with diverter, right a volume/diverter control — mounted on tile surround in a finished bathroom, no visible corrosion or supply connections exposed. Finished walk-in shower with matte black trim kit — wall-mount rain head, dual volume/diverter valves, and linear drain — set into large-format porcelain slab surround with frameless glass enclosure; no visible supply rough-in or failure modes. Frameless glass walk-in shower enclosure with matte black trim, dual rain head and handheld fixture setup on large-format porcelain slab surround with integrated bench, linear drain, and recessed niche shelf. Finished tile shower enclosure with brushed nickel pressure-balance valve trim, dual rain-head and handheld showerhead combo, wall-mounted grab bar, subway tile field with herringbone marble accent border, and frameless glass door — no visible supply rough-in or failure modes, all trim finish work. Newly tiled shower enclosure with large-format gray porcelain wall tile and mosaic floor tile, brushed nickel pressure-balance trim kit installed at standard height, tub spout arm stubbed out, no caulking or grout sealing completed yet — finish trim stage, not ready for inspection. Wall-hung commercial toilet with chrome manual flushometer valve on a chrome supply stub-out, tile-finished commercial restroom installation, no visible corrosion or scale, seat missing, minor water pooling on the floor at the base. Plumber setting trim on a new double-vanity install in a finished bathroom — braided stainless supply lines visible, brushed nickel faucets already set in granite top, drain assembly being fitted with PVC P-trap, no corrosion or prior failures present. Newly tiled commercial restroom rough-in with copper stub-out on back wall, chrome flush-valve valve body roughed in on right, two floor drains awaiting trim rings, and toilet flange with temporary red wax-ring protector cap still in place. Newly tiled bathroom rough-in with a copper stub-out protruding from the wall tile and a black ABS closet flange set in the floor tile, grout lines still open, finish fixtures not yet installed. Tile-finished shower enclosure mid-trim-out with large-format gray porcelain wall tile, mosaic floor tile, a brushed-nickel shower valve trim plate installed on the right wall, an overhead rough-in port still open, Moen packaging on site, grout bag visible, no exposed piping or visible failure modes. Two-piece elongated toilet, appears newer, set in a tight water closet with aged sheet vinyl flooring showing heavy soiling and possible subfloor moisture damage, walls showing prior water staining consistent with a long-term condensation or supply line leak history. Shower rough-in with brass valve body stubbed out on left wall, blue PEX supply stubs capped at multiple walls and ceiling, matte black handheld holder and linear drain installed, large-format porcelain tile surround mid-installation with open grout joints and bench framed in. Walk-in shower rough-finish stage with matte black trim-out fixtures — dual wall-mount and one ceiling rain head, two volume/diverter valves — large-format porcelain surround installed, linear drain set in mortar bed not yet tiled, PEX manifold with red/blue F1960 crimp rings visible on right stanchion. Finish-trim stage walk-in shower with matte black dual rain heads (ceiling-mount and wall-mount), square valve trim, large-format porcelain slab surround, linear drain at the curb, and what appears to be PEX supply still stubbed behind the wall based on the blue fittings visible at mid-wall. Matte black square-handle pressure-balance shower valve trim kit with integral diverter, wall-mounted on white tile surround, no visible corrosion, trim appears zinc or brass with PVD coating, concealed valve body behind wall. Two matte black square-handle in-wall valve trim kits mounted on a porcelain tile surround, supply valves recessed into wall with concealed rough-in bodies, no visible corrosion or material failures, protective tape still on tile edges indicating recent finish install. New construction shower trim-out with two matte black volume/diverter valves set into large-format porcelain or quartz slabs, blue PEX stub-outs capped at the bench and overhead rain-head location, linear drain at the curb — finish stage, no visible corrosion or failure modes. Two-piece elongated toilet with braided stainless supply line set in a finished bathroom, toilet not caulked to tile floor, wax ring seal condition unknown, adjacent tub/shower combo with curtain rod visible. Two vitreous china two-piece toilets staged on cardboard in a living area — tanks removed, seats still on — prepped for installation, no supply lines or wax rings visible yet. Navien tankless water heater wall-mounted in a utility alcove, plumbed with copper supply lines and a corrugated stainless gas flex connector, PVC condensate drain running overhead, with isolation valves and a pressure relief assembly at the unit connections. Navien tankless water heater wall-mounted in a utility alcove, plumbed with copper supply lines and a corrugated stainless gas flex, blue SharkBite push-fit fittings on the cold inlet, PVC condensate drain exiting the top, no visible corrosion but wall shows prior moisture staining at the base. Interior utility/garage wall showing copper supply stub-outs with a removed water heater rough-in, significant mold growth and moisture staining on drywall indicating a past or active leak, with black ABS drain piping overhead and a fire sprinkler head at ceiling. Access panel cut into drywall in what appears to be a closet, exposing copper supply lines with a looped riser and threaded fittings, with significant mold growth on surrounding drywall indicating a prior or active moisture intrusion behind the wall. Dual wall-mounted tankless water heaters with copper supply/return manifold, yellow corrugated gas connectors, blue ball valves, and an expansion tank — commercial or utility room install, no visible corrosion but flux residue present on solder joints. Dual tankless water heaters wall-mounted in a commercial utility room, plumbed in copper with yellow CSST gas flex connectors, a single expansion tank shared between units, and no visible corrosion or scale on the copper manifold assembly. Dual tankless water heaters wall-mounted in a commercial utility space, plumbed with copper supply and return manifolds, yellow CSST gas flex connectors, ball valves throughout, and a single expansion tank on the left unit. Tile wall opened up to expose copper supply lines with heavy oxidation and mineral staining feeding a brass pressure-balancing shower valve, wire mesh visible in the substrate behind the framing. Copper supply lines with sweat-soldered fittings feeding a brass pressure-balancing shower valve, accessed through a demo'd tile wall showing wire lath and mortar bed substrate, no visible corrosion but slight surface oxidation on the copper runs. Gas water heater top connections showing corrugated copper flexible supply lines on hot and cold ports with brass fittings, a sheet metal draft hood with foil-taped flue collar junction showing improper tape repair, and heavy dust accumulation on the tank top. Two parallel copper supply lines with soldered sweat couplings showing oxidation and surface tarnish, accessed through a drywall cutout revealing wood framing, with a gray electrical conduit or PVC line running below between floor joists. Freestanding acrylic jetted soaker tub set in finish-stage bathroom with brushed-gold floor-mount filler rough-in stubbed up, large-format tile and mosaic accent wall partially installed, no visible supply connections finalized yet. Gas appliance connection at a furnace or water heater showing a corroded black iron pipe elbow with a brass ball valve transitioning to a yellow CSST flexible gas connector, with active soap bubble leak test visible at the union fitting. Slab demo in progress with tile and concrete broken out to expose underslab rough-in, PEX supply lines with blue crimp fittings visible through the stud wall, concrete debris cleared for drain access or reroute. Black ABS or cast iron soil stack exposed through a demolished exterior stucco/lath wall at slab level during rough-in access work, with concrete rubble at the base indicating slab saw-cut or demo around the pipe penetration. Bathroom rough-in remodel with drywall removed, showing ABS black drain stack with a 90-degree sweep fitting, blue and white PEX supply lines stubbed out at a washer or utility box location, and NM electrical cable roughed in adjacent to framing. Bradford White gas water heater installed in an exterior closet alcove, yellow CSST flexible gas line visible at burner assembly, corrugated stainless connections at top, no visible corrosion, residential exterior rough-in with door enclosure. Cross-section of a copper supply line showing severe freeze damage — the pipe wall has catastrophically deformed and split outward, with heavy oxidation and scale buildup on the interior bore, consistent with a freeze-burst failure from water expansion. Rough-in wall framing with white PEX tubing routed through studs terminating at two black recessed valve manifold boxes, likely shower or tub rough-in valves, with copper supply visible upper center — no visible corrosion or scale at this stage. New construction rough-in with white PEX supply lines run through wood-framed studs, two black pressure-balancing shower valves (likely Moen or Delta) with PEX push-fit or crimp connections, and a copper vertical riser stubbed in at right, no visible corrosion or failure modes. Corroded copper supply lines with heavy verdigris patina transitioning to PEX repipe in a crawlspace or subfloor rough-in, with a temporary rubber repair clamp (Fernco or similar) bandaging an active leak point on the copper main. Under-slab rough-in with PVC DWV trunk lines, multiple stub-ups, and two cleanout boxes set in native soil prior to pour, with form boards and rebar stakes visible along the foundation perimeter. Slab rough-in for a residential addition showing ABS or PVC DWV stubouts with cleanouts and black vertical riser pipes laid out in trenched soil prior to concrete pour, no visible corrosion or pressure supply lines yet. Rough-in shower valve (green-handled, likely Moen Posi-Temp) stubbed out with copper supply pipe capped with a blue PEX end cap, mounted in open stud wall during active remodel with subfloor exposed. Shower valve rough-in on copper supply with heavy oxidation and verdigris on the brass mixing valve body, open stud wall remodel context, with PEX stub-outs transitioning off the copper drops — valve shows significant exterior corrosion warranting replacement before close-in. Rough-in interior wall showing a vertical copper riser stubbed to a ball valve at top with a blue CPVC or PEX-AL-PEX horizontal branch, transitioning at the base to what appears to be a shower valve rough-in with copper sweat fittings, framing exposed with no visible corrosion or scale. Opened wall and ceiling in a residential interior showing copper supply lines with soldered elbows and tees roughed into OSB-sheathed framing, alongside a black ABS or gas line and a double-wall metal B-vent or dryer duct terminating through the ceiling. Bradford White gas water heater installed in an exterior stucco-wall alcove with sheet metal enclosure, copper supply connections at top, yellow flexible gas connector at bottom, and B-vent flue exiting through the roof deck above. Exterior-installed gas water heater in a dedicated metal enclosure mounted against a stucco wall on a concrete pad, with copper supply connections at the top, a yellow gas flex connector, and a standard T&P relief valve discharge pipe visible. Interior wall opened up exposing a black ABS drain stack with a P-trap elbow, gray PEX supply lines, flexible metallic conduit, and a new outlet box mounted to studs, with fiberglass batt insulation visible and water damage staining on the tile floor indicating a prior leak event. Double-basin cultured marble or cast polymer vanity top with chrome two-handle faucets mid-renovation, supply lines disconnected, blue tape masking the apron, Goof Off solvent on deck, wet-vac staged nearby indicating demo or reseal work in progress. Commercial toilet with chrome flushometer valve installed in a tiled commercial restroom, plunger and brush visible nearby. Dual whole-house water filtration/softener tanks installed with a sediment pre-filter and copper supply lines in a garage utility area. Corroded copper pipes and a new PVC drain stub-out exposed in an under-slab excavation with broken concrete debris visible. Copper supply lines and a white PVC fitting exposed through a jackhammered opening in an exterior stucco wall during leak detection or pipe repair. Slab cut open exposing an old cast iron drain elbow and hub for access or replacement under a concrete floor. Shower valve trim removed in a tiled bathroom, exposing the cartridge body during a repair with tub spout running water. Corroded copper pipe fitting held up showing heavy internal buildup, with new replacement parts and gaskets laid out on a tile floor. Newly tiled shower surround with white subway tile and a tub valve rough-in stub-out visible in a bathroom remodel. A drain cleanout access box in a concrete floor with a drain snake being fed into the standing water below. Multiple supply and drain lines run along an exterior stucco wall, surface-mounted and secured with pipe straps. Multiple black and gray pipes strapped to an exterior stucco wall along a narrow side yard. Two insulated flexible gas lines connect to black iron pipe fittings at an exterior concrete block wall with dirt ground. Black poly pipe runs along the exterior block wall in a narrow side yard between two buildings. Black ABS drain pipes and fittings staged at an exterior building foundation alongside an exposed cleanout during drain line repair. New gas and water supply lines strapped along an exterior building wall, with drills and fittings staged on the ground during installation. Corroded copper supply manifold with multiple blue-capped stub-outs accessed through an open subfloor panel in a crawl space or under-cabinet utility area. Delta single-handle tub/shower valve leaking at the trim ring in a bathroom tub surround. Exterior water meter and pressure regulator assembly with hose bib installed at a brick foundation, excavated from dirt for repair or replacement. Navien tankless water heater installed on garage wall with PVC exhaust flue, copper supply lines, and gas connections on a raised concrete pad. Completed shower fixture install with chrome handheld showerhead on slide bar, pressure-balance valve, and glass door in a tiled bathroom. Vintage cast iron wall-mount farm sink installed in a bathroom with chrome two-handle faucet, P-trap, and supply lines roughed in. Corroded copper pipe with irrigation valve manifold penetrating a damaged exterior wall, showing active leak repair at an outdoor service location. Rheem Performance tank water heater installed in an exterior alcove with copper supply lines. Rheem tank water heater installed in an exterior side-of-house cabinet enclosure with flue vent pipe. Copper supply pipe exposed through an open drywall cutout in an interior wall during leak detection or repair.